Write expanded uncertainty U (k=2) and proving intervals directly into fiscal measurement regulations rather than brand names.
Statutory metrology specification schedule
Does a custody-transfer metering chain stay inside the statutory OIML permissible error?
01 · Live RSS budget
Statutory maximum permissible error ceiling under OIML R 117-1.
Combined meter linearity and repeatability across operating flow range (0.02% to 0.80%).
Traceable reference pipe prover or master meter uncertainty (0.01% to 0.40%).
Rectangular half-width error converted to 15 C reference volume at 0.085%/C.
Rectangular half-width pressure error converted via liquid compressibility (0.009%/bar).
Densitometer and BS&W sampling uncertainty (0.01% to 0.50%).
Annual custody-transfer throughput at USD 650/m3 illustrative value (100 to 20,000 km3).
Horizontal bars show each instrument contribution at k=2 and the RSS combined chain bar against the vertical statutory limit.
Following JCGM 100:2008 (Guide to the Expression of Uncertainty in Measurement) and OIML R 117-1, every error source is converted to a 1-sigma standard uncertainty u_i before combining in quadrature:
Limitations: assumes uncorrelated rectangular transmitter errors and steady single-phase liquid flow; two-phase entrained air, wax build-up or pulse-interpolation faults require dedicated physical diagnostics.
02 · Component ledger
| Component | Distribution | Raw input | Standard u_i (%) | Expanded 2*u_i (%) | Variance share |
|---|---|---|---|---|---|
| Primary flow meter | normal (k=2) | 0.14% | 0.0700% | 0.1400% | 60.1% |
| Master prover calibration | normal (k=2) | 0.06% | 0.0300% | 0.0600% | 11.0% |
| Temperature compensation | rectangular | 0.30 C | 0.0147% | 0.0294% | 2.7% |
| Pressure compensation | rectangular | 0.40 bar | 0.0021% | 0.0042% | 0.1% |
| Density and water cut | rectangular | 0.08% | 0.0462% | 0.0924% | 26.2% |
03 · Calibration regimes
Coriolis or turbine skid proved on-line with calibrated RTDs maintains comfortable headroom inside OIML Class 0.3.
| Regime | Expanded U (k=2) | Annual value at risk | Engineering implication |
|---|---|---|---|
| Proved fiscal skid (Class 0.3) | 0.124% | USD 2.01m | Coriolis or turbine skid proved on-line with calibrated RTDs maintains comfortable headroom inside OIML Class 0.3. |
| Baseline depot chain (default) | 0.181% | USD 2.93m | Stays inside 0.30% permissible error, though meter repeatability and density dominate over 80% of combined variance. |
| Uncalibrated meter & RTD drift | 0.362% | USD 5.89m | Breaches OIML Class 0.3 statutory limit (-0.063% headroom); fiscal custody-transfer statements become open to operator challenge. |
Comparison of expanded uncertainty and annual value at risk across proved fiscal skid, baseline depot and drifted meter regimes.
Source: Tie Wang GUM uncertainty engine (deterministic browser model)
04 · Auditor's heat
Under Sourced std-r117 · 2019 Dynamic measuring systems for liquids other than water OIML R 117-1:2019 Open public record ↗ , a Class 0.3 dynamic liquid measuring system must hold total system error within Sourced met-1 · 2019 Maximum permissible error of an accuracy class 0.3 dynamic liquid measuring system (custody transfer of crude oil and products) OIML R 117-1:2019, Dynamic measuring systems for liquids other than water Open public record ↗ while the flow meter alone stays inside Sourced met-2 · 2019 Maximum permissible error of the meter alone in the same accuracy class OIML R 117-1:2019, Dynamic measuring systems for liquids other than water Open public record ↗ , referenced to standard petroleum conditions of Sourced met-3 · 1999 Standard reference conditions for petroleum and liquid petroleum products ISO 5024:1999, Petroleum liquids and liquefied petroleum gases, measurement, standard reference conditions Open public record ↗ . Without a live uncertainty budget attached to each custody-transfer statement, an exporter or depot operator can dispute tax assessments by pointing to unverified temperature compensation or expired calibration certificates.
Tie Wang applies this budget before recommending any hardware investment. Where an existing terminal meter meets the statutory class once its resistance thermometer and flow computer are verified against an accredited Sourced std-17025 · 2017 General requirements for the competence of testing and calibration laboratories ISO/IEC 17025:2017 Open public record ↗ laboratory standard, a read-only data diode connector captures fiscal truth at a fraction of new-skid capital cost. New skids are ordered only where the uncertainty budget proves the existing plant cannot hold legal tolerance.
05 · Action by counterparty
Write expanded uncertainty U (k=2) and proving intervals directly into fiscal measurement regulations rather than brand names.
Statutory metrology specification schedule
Quantify annual value at risk (+/- U) to confirm that measurement error cannot mask throughput covenants.
Technical adviser uncertainty sensitivity audit
Target capital at the dominant variance contributor shown above before replacing an entire metering skid.
Ranked calibration and transmitter upgrade list
Align national weights-and-measures laboratory accreditation with ISO/IEC 17025 proving traceability.
National proving and witness-calibration calendar